PENNCO PNC1604HSID

PENNCO 16 Series 1604HSID 354541106 Gas Fired Steam Boiler, 82 % AFUE, 112000 Btu/hr BTU, Natural Gas Fuel, Cast-Iron

Manufacturer: BDR Thermea Group
Part #: PNC1604HSID
Customer Part #:
Login for Availability
Login for Price
AFUE Rating      :      82 %
Area      :      283 sq-ft
BTU Rating      :      112000 Btu/hr
Connection Type      :      (2) 2-1/2 in Supply/Return, 3/4 in Drain
Dimensions      :      41-7/8 in H x 26-1/2 in D
Flue Diameter      :      6 in
Fuel Type      :      Natural Gas
Material      :      Cast-Iron
Model      :      1604HSID
Net BTU Rating      :      68000 Btu/hr
Series      :      16 Series
Vent Type      :      Chimney

PENNCO Gas Fired Steam Boiler, 16 Series, Model: 1604HSID, 82 % AFUE, 112000 Btu/hr BTU, (2) 2-1/2 in Supply/Return, 3/4 in Drain Connection, Natural Gas Fuel, Chimney Vent, 6 in Diameter Flue, Net BTU Rating: 68000 Btu/hr, 283 sq-ft Area, Cast-Iron, Dimensions: 41-7/8 in H x 26-1/2 in D

  • 4-sections
  • Cast iron sections and push nipples, heat exchanger is constructed of heavy-duty cast iron sections and sealed with cast iron push nipples
  • Integral draft diverter is built-into the boiler and protects against harmful back drafts to ensure safe operation, exhaust pipe can be installed directly from the top of the boiler enabling safe installation in sites with low ceiling height
  • Steam chest and supply tappings incorporates a 6 in steam chest which allows the boiler to generate ample amounts of steam, 2-1/2 in supply tappings provide easy access for steam to enter your distribution system and heat your home quickly
  • Low water cut-off, pressuretrol and 15 lb pop safety valve are standard and ensure safe, reliable operation
  • Every 16 Series boiler is test fired at our factory prior to shipping to ensure safe, reliable operation
  • 24 V, 40 V-A transformer
  • Pressure limit control
  • Electronic probe type low water cut-off
  • Flame roll-out safety shut-off fuse link and blocked vent safety shut-off switch
  • Glass water level gauge
  • Steam pressure gauge
  • (2) 2-1/2 in square head pipe plugs used to plug unused supply and return tappings
  • Continuous pilot with vent damper
  • Complete installation instructions
  • Completely installed and wired gas control system with burners and manifold, consisting automatic redundant combination gas valve, 24 V, with pilot filter
  • Intermittent pilot control with vent damper, continuous retry, 100% shut-off, combination pilot/burner/electrode/flame sensor

back To Top