| Additional Information | : | 13-9/16 in D Dimensions, R-410A Refrigerant |
| Amperage Rating | : | 20 A |
| BTU Rating | : | 36000 Btu/hr, 40000 Btu/hr |
| CFM Rating | : | 699 cfm, 752 cfm, 830 cfm, 3532 cfm |
| Connection Type | : | 3/8 in Flared High Side, 5/8 in Flared Low Side, 1 in ID x 1-1/4 in OD Condensate |
| Drive Type | : | Inverter |
| EER Rating | : | 9.5 |
| Frequency Rating | : | 60 Hz |
| Fuse Rating | : | 35 A |
| HSPF Rating | : | 8.5 |
| Mounting Type | : | Wall |
| Number of Fan Speeds | : | 3 |
| Overall Height | : | 9-15/16 in |
| Overall Width | : | 50-3/8 in |
| Phase | : | 1 ph |
| Power Rating | : | 58 W, 125 W |
| SEER Rating | : | 19.2 |
| Sound Level | : | 38 dB, 46 dB, 48 dB, 51 dB |
| Temperature Rating | : | 61 to 90 deg F Cooling, <=86 deg F Heating |
| Voltage Rating | : | 208 to 230 V |
Samsung Evaporator Indoor Split System, 208 to 230 V, 20 A, 58 W, 125 W, 60 Hz, 1 ph, 3 Number of Fan Speeds, 36000 Btu/hr, 40000 Btu/hr, 699 cfm, 752 cfm, 830 cfm, 3532 cfm Rating, 9.5 EER, 19.2 SEER, HSPF: 8.5, 3/8 in Flared High Side, 5/8 in Flared Low Side, 1 in ID x 1-1/4 in OD Condensate Connection Type, 35 A Fuse, Inverter Drive, 38 dB, 46 dB, 48 dB, 51 dB, Wall Mount, 61 to 90 deg F Cooling, <=86 deg F Heating, 50-3/8 in Overall Width, 9-15/16 in Overall Height, Additional Information: 13-9/16 in D Dimensions, R-410A Refrigerant
- High voltage terminal block temperature sensor to disable unit in the event of power connection overheating
- Auto restart after power loss
- Soft start compressor minimizing current inrush
- All heat exchangers shall be mechanically bonded aluminum fin to copper tube
- The condensing unit heat exchanger salt spray test method ASTMB117-18 the heat exchanger showed no unusual rust or corrosion development to 2280 hr
- Indoor fan is a single crossflow type
- Three-fan speed settings and auto setting
- Washable filter as standard
- Control wiring shall be 2 a 16 AWG
- Wireless controller included as standard
- Wired controllers must be purchased separately
- Dual set temperature support when connected to MWR-WG00UN advanced wired controller and supported central control
- No additional interface modules/adapters are required when connecting to Samsung central control options
- The unit shall be operated via a wireless or wired remote control with DDC-type signal
- The compressor shall be hermetically sealed, inverter controlled twin BLDC rotary-type
- Refrigerant flow shall be controlled by an electronic expansion valve at the outdoor unit