| Amperage Rating | : | 1.4 A |
| BTU Rating | : | 60000 Btu/hr Cooling/Heating |
| CFM Rating | : | 4500 cfm |
| Coil Rating | : | 23.65 sq-ft Face Area, 20 FPI |
| Compressor Type | : | Variable Speed Rotary |
| Connection Type | : | Sweat |
| Dimensions | : | 31-3/16 in L x 31-3/16 in W x 42-5/16 in H |
| Drive Type | : | Forward Swept/Propeller Direct |
| EER Rating | : | 10 |
| Finish | : | Baked-On Powder-Coated/Galvanized |
| Frequency Rating | : | 60 Hz |
| Fuse Rating | : | 60 A |
| HP Rating | : | 1/3 hp |
| HSPF Rating | : | 10 |
| Liquid Line Size | : | 3/8 in |
| Material | : | Steel |
| Phase | : | 1 ph |
| Refrigerant Type | : | R-410A |
| Rotational Speed | : | 900 rpm |
| SEER Rating | : | 18 |
| Series | : | TVH8 Series |
| Sound Level | : | 71 to 72 dBA |
| Tonnage | : | 5 ton |
| Voltage Rating | : | 208-230 V |
TEMPSTAR® Heat Pump, TVH8 Series, 208-230 V, 1.4 A, 1/3 hp, 60 Hz, 1 ph Phase, 900 rpm Rotational Speed, 60000 Btu/hr Cooling/Heating, 4500 cfm, 10 EER Rating, 18 SEER, 10 HSPF, Sweat Connection, Variable Speed Rotary Compressor, R-410A Refrigerant, 3/8 in Liquid Line, 60 A Fuse Rating, 23.65 sq-ft Face Area, 20 FPI Coil, Forward Swept/Propeller Direct Drive, Tonnage: 5 ton, 71 to 72 dBA Sound Level, Steel, Finish: Baked-On Powder-Coated/Galvanized, 31-3/16 in L x 31-3/16 in W x 42-5/16 in H
- Variable-speed heat pump with observer communicating control system
- Variable-speed compressor operates at five-stage with capacity range as wide as 25 to 100%
- Electronic expansion valve (EXV) for precise heating control
- High pressure switch
- Suction pressure transducer
- Pressure equalizer valve for easy starting
- Compressor discharge temperature sensor, coil temperature sensor
- Copper tube/aluminum fin coils, internal crankcase heater standard, suction line accumulator factory installed
- Integrated inverter control enables five-stage operation with complete observer communicating system including observer control - observer wall control with version five or newer software required, also capable of two-stage operation with two-stage thermostat
- Self-configuring installation capabilities with observer communicating wall control, compact ECM fan motor driven by integrated inverter control, outdoor temperature sensor factory installed
- High performance compressor sound shield standard, isolation compressor grommets, enhanced dehumidification
- Text based diagnostics with observer communicating wall control, only two-control wires required from communicating indoor unit to condenser, external high and low refrigerant service ports
- Factory charged with R-410A refrigerant, adjustments for min and max staging with observer wall control
- High gloss, baked-on powder-coated finish over galvanized steel, post-painted (black) coil fins
- Coated inlet grille with 3/8 in grille spacing for extra protection
- Corner posts for extra strength and style
- Coil guard grille
- Sales code